Lesson 10 · 4:01
Manufactured Home
The section a manufactured home adds: manufacturer, installation and foundation, width and skirting, the HUD data plate, and the HUD labels and their photos.
Transcript
Manufactured Home
The 1004C addendum is gone: a manufactured home now gets its own section inside the URAR. It appeared when we chose the Manufactured construction method, and it records what's specific to the home: who built it, how it's installed, and its HUD data plate and labels. Open it from the section list.
Maker and installation
Manufacturer Name: this home was built by Fleetwood Homes. Year Installed is the year a certificate of occupancy, or its equivalent, was issued for placing the home on its foundation. Here that's 1998, the year it was built, and it isn't an estimate. Moved Since Original Installation: No. The home is still on the site where it was first installed. Attached to Permanent Foundation: Yes. The foundation itself, concrete block piers over a crawl space, is already described in Dwelling Exterior. Towing Hitch, Wheels, Axles Removed: Yes, they've all been taken off the frame. Manufactured Home Width: the home was built in two sections and joined on site, so it's Multi.
Skirting and modifications
Skirting is the non-structural enclosure around the crawl space. It exists, so answer Yes, and pick its material: wood. The last question asks whether any modification, attachment or addition relies on the home for support, or has altered its structure. Nothing has, so No.
When the plate is missing
Next, the HUD Data Plate: the paper certificate, usually inside a kitchen cabinet or a closet, that records how and where the home was built. It wasn't found in this home, so HUD Data Plate Attached is No. The information is still available from other records, so we report it. Date of Manufacture: December 2nd, 1998. Its year has to match Year Built in Dwelling Exterior, and it does. The serial number, with one for each section, comes next. Then the HUD zones the home was designed and built for, which set its wind, thermal and roof load design: Wind Zone One, Thermal Zone Three, and Roof Load Zone South. When the plate isn't attached, UAD asks us to say in Manufactured Home Commentary where this information came from. We'll do that further down.
One label per section
The HUD Certification Label is the metal tag on the outside of each section. Both sections have one, so Label Present for All Sections is Yes. Enter each section's label number: WAS091752, then add an entry for WAS091753. A photo of every label is required, clear enough to show it. Open Files from the right-hand rail, find each photo by name, and drag it onto the HUD Certification Label Photo gallery: first the label on the south side of the home, then the north side. Caption each photo with where it was taken: South Side, and North Side.
What doesn't apply
The Manufactured Home Certification Program is for homes built to MH Advantage or CHOICEHome. This one isn't, so it stays empty. And the invoice questions only appear for new construction.
Source of the data
In Manufactured Home Commentary, explain where the data plate information came from, since the plate isn't in the home. Say where the label numbers came from, too. F-1 also asks for a photo of the foundation, when it's accessible. Open Files again, drag the crawl space photo into Manufactured Home Exhibits, and caption it Foundation. It asks for a photo of the skirting too, when it's readily accessible. Drag in the photo of the wood skirting, and caption it Skirting.
Functional Obsolescence
That's the Manufactured Home section. Next, Functional Obsolescence.