Dwelling Exterior

Dwelling Exterior describes the outside of the building: its design and age, how it was built, the exterior's quality and condition, and its mechanical systems. A 2-4 unit property gets one Dwelling Exterior per building; all four units here share one. Open it from the section list.

Style and entry

Dwelling Style is required. This is a two-story brick building with a symmetrical front and a center entrance: a Colonial. Front Door Elevation is how high the front door sits above the ground. The entry is up a short flight of steps, three to four feet.

Year built

Year Built, 1941, came in from the listing, and it isn't an estimate. Converted Area asks whether part of the building was converted from another use, like a garage turned into living space. Not here, so No. Construction Method came in as Site Built. Structure Volume is only needed when the client asks for it, so we leave it blank.

Exterior ratings

Exterior Quality Rating uses the Q scale. Standard materials and workmanship for its era: Q4. Exterior Condition Rating uses the C scale. The building is well maintained, with only normal wear and no repairs needed: C3.

Walls

Each exterior component gets its materials and condition. The walls came in as brick, and they show typical wear and tear.

Over a basement

Foundation Type came in from the listing as Slab. But the sketch shows a full basement under the building, with an entrance at the rear, so change the type to Basement. That makes Foundation Material required. The basement walls are brick, in typical wear and tear.

Roof and windows

The flat roof was observed at the inspection, so Observable is Yes. Its material is tar and gravel. Estimated Age is ten to twenty years, and the condition is typical wear and tear. Describe the windows: storm and sash windows. Then their condition: typical wear and tear.

Noncontinuous finished area

Noncontinuous Finished Area is finished space attached to the dwelling that can't be reached from inside it. UAD asks it only of a one-unit property. It shows now because the listing came in as a single unit; once we set up all four units, the question goes away, so we leave it blank.

Heating and cooling

The heating system came in from the listing as radiators. The inspection found forced warm air, fueled by natural gas, so change the system type. Has Cooling System is Yes. The type is Individual: each unit is cooled by its own window units. Core Heating System Below Grade asks whether the main heating equipment is below grade. It's in the basement, so Yes.

Defects

Last, Dwelling Exterior Defects Exist. The inspection found no exterior defects, damage or deficiencies, so choose No.

Functional Obsolescence

The front and rear photos go in the exhibits below; we'll place the inspection photos later in the course. That's Dwelling Exterior. Next, Functional Obsolescence.